Specifications |
| |
General |
| Function |
Microprocessor-based In-Line Mass Flow Meters for gases |
| Flow
Element |
Constant Temperature Thermal Mass Flow
Element consists of two
316 SS clad platinum-wound
RTDs |
| Flow Rate Output
Signal |
4-20 ma isolated output linearly proportional to mass flow rate |
| Temperature Output
Signal |
0-5 VDC linear
temperature signal from 40°F to 200°F
(i.e. this product has both a flow and temperature output) |
| Power |
24 VDC with current dissipation of less than 250 ma, or 115VAC/230 VAC |
| Communication |
RS232 Communication Menuing Software (optional) |
| Sensor Drive Circuit |
Proprietary Sensor Drive Circuit provides
enhanced
flow signal stability and insensitivity to process
temperature
changes |
| Display / Keypad |
SRL Model is a blind format (No Display or Keypad). Remote styles do not require
electronics at sensor Junction Box |
| Menu Navigation |
RS232 Communication and Menuing Software (Sage VIP) upon request |
| |
Flow Range / Sizes |
| Units of Measurement |
Flow–SCFM, SCFH, SCFD,
SCCM,
NCMM, NCMH, KG/S, KG/M, KG/H, KG/D, LBS/S, LBS/M,
LBS/H,
LBS/D, SLPM, SLPH;
Temperature–°C and °F |
| In-Line
Meters |
Full Scale up to 3150 SCFM (4" Flow
Meter).
Resolve as low as .003 SCFM (1/4" Flow Meter). Male
NPT
fittings standard. 150# and 300# flanged ends
optional |
| |
Performance |
| Standard Flow
Accuracy |
+/-1% of Reading +0.5% of
Full Scale |
| Repeatability |
0.2% of
Full Scale |
| Turndown |
Up to 1000:1 |
| Calibration |
Sage Metering’s National
Institute of Standards Traceable (NIST) calibration
facility |
| Gas Temperature |
Std.:
-40°F to 200°F (-40°C to 93°C ); HT01:
200°F to 350°F (93°C
to 177°C ) |
| Remote Enclosure Temperature |
0° to 150°F (-18°C to
65°C ). Contact Sage for lower temperature ranges |
| Pressure Rating |
500 psig (1000 psig
optional) |
| Response Time |
1 second
(each time constant) for flow change |
| Pulsed Outputs |
Configurable for Pulsed Outputs of Totalized Flow
(in lieu of Flow Rate and Temperature) |
| Wetted Parts |
316L Stainless Steel for Flow Bodies, Sensor
Flow Elements and Flow Conditioners. Hastelloy (recommended
for Chlorine Gas) and other materials
optional |
| Limited Warranty |
Sage Metering's
Series of Thermal Mass Flow Meters are warranted against
faulty materials or workmanship for one year from the date of
delivery to the buyer. After issuance of a Return Meter
Authorization (RMA) by Sage, and upon receipt of the defective
meter, Sage will either repair or replace the defective meter
at its sole option and at no cost to the
purchaser |