DOWNLOAD DATA SHEET

 

General Information
STYLE: Remote Insertion Mass Flow Meter
SENSOR: Two reference-grade platinum RTD clad in 316SS sheath or Hastelloy C276
MATERIAL: Wetted metal components: 316SS or Hastelloy C276
POWER: 24VDC Standard (90-265VAC optional)
POWER DISSIPATION: <2.5 W
ELECTRONICS: Microprocessor-based (Hybrid-Digital)
REMOTE ENCLOSURE: Junction Box is Explosion Proof, Class I, Div. 1, Groups B, C, D (no electronics)
ELECTRONICS ENCLOSURE: NEMA 4 enclosure
DISPLAY: Flow Rate, Totalizer & Temperature (optional).
TURNDOWN: 100 to 1
RESOLUTION: 1000 to 1
LOW-END SENSITIVITY: 5 SFPM
FIELD CALIBRATION CHECK: Yes – Digital system allows raw signal validation (milli-watts)
COMMUNICATIONS: Modbus® compliant RS485 RTU
APPROVALS: Class I, Div 2, Groups B, C, D T4 (24VDC) ANSI/ISA 12.12.01, CSA C22.2;
CE (AC Power or 24VDC)
FIELD RECONFIGURABLE: SageCom and Modbus required
FLOW ACCURACY: +/- 0.5% of Full Scale +/- 1% of reading
FLOW REPEATABILITY: 0.2%
RESPONSE TIME: 1 second time constant
GAS TEMPERATURE RANGE: Standard -40° to 200°F (93°C), Optional to 300°F (149°C) and 450°F (232°C)
GAS PRESSURE: 500 PSIG (If higher pressure needed, contact Sage)
FLOW OUTPUT: 4 to 20 mA for Rate
TOTALIZER: 24VDC pulse for Totalized value
TEMPERATURE OUTPUT: Through Modbus® only
AMBIENT TEMPERATURE: -40°F to 150°F (66°C)
PROBE STYLE / LENGTH: 1/2″ OD Probe (3/4″ optional) Lengths 6″ to 36″
RELAYS: N/A
CABLE LENGTH: 25′ Standard (max length 1000′) lead length compensation is standard
FLOW CONDITIONING: Captive Flow Conditioners available upon request with meter purchase
TRANSMITTER ENCL DEPTH: DC: 4.35″ ; AC: 5.35″
This entry was posted in . Bookmark the permalink.