DOWNLOAD DATA SHEET

 

General Information
STYLE:Remote Insertion Mass Flow Meter
SENSOR:Two reference-grade platinum RTD clad in 316SS sheath or Hastelloy C276
MATERIAL:Wetted metal components: 316SS or Hastelloy C276
POWER:24VDC Standard (90-265VAC optional)
POWER DISSIPATION:<2.5 W
ELECTRONICS:Microprocessor-based (Hybrid-Digital)
REMOTE ENCLOSURE:Junction Box is Explosion Proof, Class I, Div. 1, Groups B, C, D (no electronics)
ELECTRONICS ENCLOSURE:NEMA 4 enclosure
DISPLAY:Flow Rate, Totalizer & Temperature (optional).
TURNDOWN:100 to 1
RESOLUTION:1000 to 1
LOW-END SENSITIVITY:5 SFPM
FIELD CALIBRATION CHECK:Yes – Digital system allows raw signal validation (milli-watts)
COMMUNICATIONS:Modbus® compliant RS485 RTU
APPROVALS:Class I, Div 2, Groups B, C, D T4 (24VDC) ANSI/ISA 12.12.01, CSA C22.2;
CE (AC Power or 24VDC)
FIELD RECONFIGURABLE: SageCom and Modbus required
FLOW ACCURACY:+/- 0.5% of Full Scale +/- 1% of reading
FLOW REPEATABILITY:0.2%
RESPONSE TIME:1 second time constant
GAS TEMPERATURE RANGE:Standard -40° to 200°F (93°C), Optional to 300°F (149°C) and 450°F (232°C)
GAS PRESSURE:500 PSIG (If higher pressure needed, contact Sage)
FLOW OUTPUT:4 to 20 mA for Rate
TOTALIZER:24VDC pulse for Totalized value
TEMPERATURE OUTPUT:Through Modbus® only
AMBIENT TEMPERATURE:-40°F to 150°F (66°C)
PROBE STYLE / LENGTH:1/2″ OD Probe (3/4″ optional) Lengths 6″ to 36″
RELAYS:N/A
CABLE LENGTH:25′ Standard (max length 1000′) lead length compensation is standard
FLOW CONDITIONING:Captive Flow Conditioners available upon request with meter purchase
TRANSMITTER ENCL DEPTH:DC: 4.35″ ; AC: 5.35″