General Information |
STYLE: |
Integral In-Line Mass Flow Meter |
SENSOR: |
Two reference-grade platinum RTD clad in 316SS sheath |
MATERIAL: |
Wetted metal components: 316SS |
POWER: |
24VDC Standard (90-265VAC optional) |
POWER DISSIPATION: |
<2.5 W |
ELECTRONICS: |
Microprocessor-based (Hybrid-Digital) |
ELECTRONICS ENCLOSURE: |
Integral mount, NEMA 4 enclosure |
DISPLAY: |
Flow Rate, Totalizer & Temperature (optional). |
TURNDOWN: |
100 to 1 |
RESOLUTION: |
1000 to 1 |
LOW-END SENSITIVITY: |
5 SFPM |
COMMUNICATIONS: |
Modbus® compliant RS485 RTU |
APPROVALS: |
Class I, Div 2, Groups B, C, D T4 (24VDC) ANSI/ISA 12.12.01, CSA C22.2; |
|
CE (AC Power or 24VDC) |
FIELD RECONFIGURABLE: |
SageCom and Modbus required |
FLOW ACCURACY: |
+/- 0.5% of Full Scale +/- 1% of reading |
FLOW REPEATABILITY: |
0.2% |
RESPONSE TIME: |
1 second time constant |
GAS TEMPERATURE RANGE: |
Standard -40° to 200°F (93°C), Optional to 300°F (149°C) and 450°F (232°C) |
GAS PRESSURE: |
500 PSIG (If higher pressure needed, contact Sage) |
FLOW OUTPUT: |
4 to 20 mA for Rate |
TOTALIZER: |
24VDC pulse for Totalized value |
TEMPERATURE OUTPUT: |
Through Modbus® only |
AMBIENT TEMPERATURE: |
-40° to 150°F (66°C) |
FLOW BODY: |
316SS Schedule 40 Flow Bodies sized from 1/4″ x 6″ long to 4″ x 12″ long. |
|
Male NPT ends standard (Flanges and other options available) |
RELAYS: |
N/A |
FLOW CONDITIONING: |
Flow Conditioners are built into In-Line Style Flow Bodies from 1/2″ to 4″ |
ENCLOSURE DEPTH: |
DC: 4.35″ ; AC: 5.35″ |