DOWNLOAD DATA SHEET

General Information
STYLE:Remote Insertion Mass Flow Meter
SENSOR:Two reference-grade platinum RTD clad in 316SS sheath
MATERIAL:Wetted metal components: 316SS
POWER:24VDC Standard (12VDC or 115/230VAC optional)
POWER DISSIPATION:< 2.5 w
ELECTRONICS:Microprocessor-based (Hybrid-Digital)
PROBE ENCLOSURE:Junction Box is Explosion Proof, Class I, Div 2, Groups B, C, D (no electronics)
ELECTRONICS ENCLOSURE:Integral mount, NEMA 4 enclosure
DISPLAY:High contrast photo-emissive OLED graphical display (Flow rate, Totalizer, Temperature)
TURNDOWN:100 to 1
RESOLUTION:1000 to 1
LOW-END SENSITIVITY:5 SFPM
FIELD CALIBRATION CHECK:Yes – Digital system allows raw signal validation (milli-watts)
COMMUNICATIONS:Modbus® compliant RS485 RTU or optional HART® communications
APPROVALS:Class I, Div, 2 Groups B, C, D T4. (24 VDC). ANSI/ISA 12.12.01, CSA 2202; ATEXnA – Div 2 (24 VDC)
FIELD RECONFIGURABLE:SageCom required
FLOW ACCURACY:+/- 0.5% of Full Scale +/- 1% of reading (Enhanced accuracy optionally available with limited turn-down)
FLOW REPEATABILITY:0.2%
RESPONSE TIME:1 second time constant
GAS TEMPERATURE RANGE:Standard -40 ° to 200 °F (93 °C), Optional to 300 °F (149 °C) and 450 °F (232 °C)
GAS PRESSURE:500 PSIG (if higher pressure needed, contact Sage)
FLOW OUTPUT:4 to 20 mA for Rate
TOTALIZER:24VDC pulse for Totalized value
TEMPERATURE OUTPUT:Through Modbus® only
AMBIENT TEMPERATURE:-40 ° to 150 °F (66 °C)
PROBE STYLE / LENGTH:1/2″ OD Probe (3/4″ optional) Lengths 6″ to 36″
RELAYS:N/A
CABLE LENGTH:25′ Standard (max length 1000′)
FLOW CONDITIONING:Captive Flow Conditioners available upon request with meter purchase
ENCLOSURE DEPTH:DC: 4.35″ AC: 5.35″
This entry was posted in . Bookmark the permalink.