DOWNLOAD DATA SHEET

General Information
STYLE:Integral In-Line Mass Flow Meter
SENSOR:Two reference-grade platinum RTD clad in 316SS sheath
MATERIAL:Wetted metal components: 316SS
POWER:24VDC Standard (90-265VAC optional)
POWER DISSIPATION:<2.5 W
ELECTRONICS:Microprocessor-based (Hybrid-Digital)
ELECTRONICS ENCLOSURE:Integral mount, NEMA 4 enclosure
DISPLAY:Flow Rate, Totalizer & Temperature (optional).
TURNDOWN:100 to 1
RESOLUTION:1000 to 1
LOW-END SENSITIVITY:5 SFPM
COMMUNICATIONS:Modbuså¨ compliant RS485 RTU
APPROVALS:Class I, Div 2, Groups B, C, D T4 (24VDC) ANSI/ISA 12.12.01, CSA C22.2;
CE (AC Power or 24VDC)
FIELD RECONFIGURABLE:SageCom and Modbus required
FLOW ACCURACY:+/- 0.5% of Full Scale +/- 1% of reading
FLOW REPEATABILITY:0.2%
RESPONSE TIME:1 second time constant
GAS TEMPERATURE RANGE:Standard -40å¡ to 200å¡F (93å¡C), Optional to 300å¡F (149å¡C) and 450å¡F (232å¡C)
GAS PRESSURE:500 PSIG (If higher pressure needed, contact Sage)
FLOW OUTPUT:4 to 20 mA for Rate
TOTALIZER:24VDC pulse for Totalized value
TEMPERATURE OUTPUT:Through Modbuså¨ only
AMBIENT TEMPERATURE:-40å¡ to 150å¡F (66å¡C)
FLOW BODY:316SS Schedule 40 Flow Bodies sized from 1/4″ x 6″ long to 4″ x 12″ long.
Male NPT ends standard (Flanges and other options available)
RELAYS:N/A
FLOW CONDITIONING:Flow Conditioners are built in to In-Line Style Flow Bodies from 1/2″ to 4″
ENCLOSURE DEPTH:DC: 4.35″ ; AC: 5.35″
This entry was posted in . Bookmark the permalink.