| General Information | |
|---|---|
| STYLE: | Integral In-Line Mass Flow Meter |
| SENSOR: | Two reference-grade platinum RTD clad in 316SS sheath |
| MATERIAL: | Wetted metal components: 316SS |
| POWER: | 24VDC Standard (90-265VAC optional) |
| POWER DISSIPATION: | <2.5 W |
| ELECTRONICS: | Microprocessor-based (Hybrid-Digital) |
| ELECTRONICS ENCLOSURE: | Integral mount, NEMA 4 enclosure |
| DISPLAY: | Flow Rate, Totalizer & Temperature (optional). |
| TURNDOWN: | 100 to 1 |
| RESOLUTION: | 1000 to 1 |
| LOW-END SENSITIVITY: | 5 SFPM |
| COMMUNICATIONS: | Modbuså¨ compliant RS485 RTU |
| APPROVALS: | Class I, Div 2, Groups B, C, D T4 (24VDC) ANSI/ISA 12.12.01, CSA C22.2; |
| CE (AC Power or 24VDC) | |
| FIELD RECONFIGURABLE: | SageCom and Modbus required |
| FLOW ACCURACY: | +/- 0.5% of Full Scale +/- 1% of reading |
| FLOW REPEATABILITY: | 0.2% |
| RESPONSE TIME: | 1 second time constant |
| GAS TEMPERATURE RANGE: | Standard -40å¡ to 200å¡F (93å¡C), Optional to 300å¡F (149å¡C) and 450å¡F (232å¡C) |
| GAS PRESSURE: | 500 PSIG (If higher pressure needed, contact Sage) |
| FLOW OUTPUT: | 4 to 20 mA for Rate |
| TOTALIZER: | 24VDC pulse for Totalized value |
| TEMPERATURE OUTPUT: | Through Modbuså¨ only |
| AMBIENT TEMPERATURE: | -40å¡ to 150å¡F (66å¡C) |
| FLOW BODY: | 316SS Schedule 40 Flow Bodies sized from 1/4″ x 6″ long to 4″ x 12″ long. |
| Male NPT ends standard (Flanges and other options available) | |
| RELAYS: | N/A |
| FLOW CONDITIONING: | Flow Conditioners are built in to In-Line Style Flow Bodies from 1/2″ to 4″ |
| ENCLOSURE DEPTH: | DC: 4.35″ ; AC: 5.35″ |