SAGE PRIME™ THERMAL MASS FLOW METER FOR GASES
Sage Prime: Lowest energy usage of any Thermal Mass Flow Meter
Sage Prime™ is our most popular gas Thermal Mass Flow Meter preferred by our Industrial, Environmental and Commercial customers for a variety of applications. It is packaged in a robust, yet lightweight, dual-sided NEMA 4 enclosure with easy access to a separate rear compartment. Large, well marked terminals provide ease of customer wiring, providing full Modbus® compliant RS485 communications, isolated 4-20mA outputs, pulsed outputs of totalized flow, and the choice of 24VDC or 115VAC/230VAC operation (12 VDC Optional). The Prime can be incorporated into almost any Gas Flow application, is CE compliant, and meets UL, CSA and ATEX standards for hazardous service. It features a bright, high contrast graphical display (organic LEDs) reporting Flow Rate, Total and Temperature and even provides the raw calibration milliwatts (mw) for diagnostics which is the key to our popular, money saving, In-Situ Calibration Check.
High contrast photo-emissive OLED display with numerical Flow Rate,Total and Temperature, as well as Graphical Flow Indicator
- Photocell activated Screen Saver to extend display life
- Calibration milliwatts (mw) is continuously displayed, providing for ongoing diagnostics, and In-Situ calibration check
- Modbus® compliant RS485 RTU communications
- Isolated 4-20 mA output
- Rugged, user-friendly packaging with easy terminal access
- Option for Solar Energy use (12VDC models)
- Low Power dissipation, less than 2.5 Watts (e.g. under 100 mA at 24 VDC). Lowest power usage of any Thermal Mass Flow Meter.
- Powerful state-of-the-art microprocessor technology for high performance mass flow measurement and low cost-of-ownership
- Proprietary digital sensor drive circuit provides enhanced signal stability and improved temperature compensation
- Remote Style has Lead-Length compensation. Transmitter can be remotely mounted up to 1000 feet from probe; Explosion Proof Junction Box has no circuitry, just terminals (suitable for harsh environments)
- Field reconfigurability via Addresser software
- Flow conditioning built into In-Line flow meters (1/2" and up)
- Captive Flow Conditioners for Insertion meter applications, if required
|
|
||||||||||
|
SAGE PRIME™STYLES AND SPECIFICATIONS Sage Metering is your source for monitoring,measuring and controlling the gas mass flow in your industrial process, building management system or environmental application. Our high performance, NIST Traceable,Thermal Mass Flow Meters will help increase productivity, reduce energy costs, maximize product yields, and/or help reduce environmental insult. Sage provides high quality In-line and Insertion hermal Mass Flow Meters for a wide variety of industrial, commercial, and environmental monitoring needs, including carbon credit verification for Greenhouse Gas reduction. Our experienced application engineers, many of whom have worked in the Thermal Mass Flow marketplace since its inception,will assist you in choosing the proper gas Flow Meter for your application – and they will be pleased to offer installation guidance to assure that the meter(s) selected will perform as accurately as possible. Additionally, our Service Staff stand ready to support you with any after-sale assistance that you may require. PRIME SIP/SRP Accuracy(4) is +/– 0.5% of Full Scale +/– 1% of reading with a turn-down of 100 to 1 and resolution as much as 1000 to 1. Repeatability is 0.2%.The Flow Meter is Sage Metering, Inc. PRIME Series,with the trade name Sage Prime™. The electronics has an isolated 4 to 20 ma output proportional to Mass Flow Rate as well as pulsed outputs of Totalized Flow (24 VDC solid state transistor drive). In addition,Modbus RS485 RTU communications is standard (IEEE 32 Bit Floating Pt). |
|||||||||||
|
|||||||||||
|
|||||||||||
|
ENGINEERING SPECIFICATIONS OF OPTIONAL SAGE PRIME PLUS This is an optional version of Sage Prime offering a separate ground for the 24VDC Power Supply (optional 5 VDC or 12 VDC Power Supplies) which isolates the Modbus ground from the power supply ground.All other features of Prime PLUS are identical to the standard Sage Prime, except Approvals do not apply at this time. |
|||||||||||
|
|||||||||||
|
|||||||||||
|
All Rights Reserved. ©2002-2010 SAGE METERING, INC. 8 Harris Court, Building D1, Monterey, CA 93940 |
|||||||||||
- Sage Prime "SIP" In-Line
- Sage Prime "SIP" Insertion
- Sage Prime "SRP" In-Line
- Sage Prime "SRP" Insertion
![]() |
Sage SIP Specifications Integral Style Prime In-line Mass Flow Meter | ![]() |
| Sage Prime Thermal Mass Flow Meter | Document No. 100-0108 Rev. 6 |
| General Information | |
|---|---|
| Style: | Integral In-line Mass Flow Meter |
| Sensor: | Two reference grade platinum RTD clad in 316SS sheath |
| Material: | Wetted metal components: 316SS |
| Power: | 24VDC Standard (12VDC or 115/230VAC optional) |
| Power Dissipation: | < 2.5w |
| Electronics: | Microprocessor based |
| Electronics Enclosure: | Integral mount, NEMA 4 enclosure |
| Display: | High contrast photo-emissive OLED graphical display (Flow rate, Totalizer, Temperature) |
| Turndown: | 100 to 1 |
| Resolution: | 1000 to 1 |
| Low End Sensitivity: | 5 SFPM |
| Field Calibration Check: | Yes - Digital system allows raw signal validation (milli-watts) |
| Communications: | Modbus® compliant RS485 RTU communications |
| Approvals: | CSA C22.2 (24VDC); Uli604, Class 1, Div 1 & 2, Grps A, B, C, D T4(24VDC); CE (AC Power or 24VDC) ATEX: Ex, nA IIC T4X (24VDC Model Only) |
| Field Reconfigurable: | Yes - Sage ADDRESSER or Sage DONGLE |
| Flow Accuracy: | +/- 0.5% of Full Scale +/-1 % of reading |
| Flow Repeatability: | 0.2% |
| Response Time: | 1 second |
| Gas Temperature Range: | -40° TO 200° STD (if higher temperature needed, contact Sage) |
| Gas Pressure: | 500 PSIG (if higher pressure needed, contact Sage) |
| Flow Output: | 4 to 20 mA for rate; 24VDC pulse for totalized value |
| Temperature Output: | Through Modbus® only |
| Ambient Temperature: | -4° F TO 150° F |
| Flow Body: |
316SS Schedule 40 Flow Bodies sized from 1/4" x 6" long to 4" to 12" long. Male NPT ends standard (Flanges and other options available) |
| Relays: | N/A |
| Flow Conditioning: | Flow Conditions are built into In-line Style Flow Bodies from 1/2" to 4" |
![]() |
Sage SIP Specifications Integral Style Prime Insertion Mass Flow Meter | ![]() |
| Sage Prime Thermal Mass Flow Meter | Document No. 100-0107 Rev.7 |
| General Information | |
|---|---|
| Style: | Integral Insertion Mass Flow Meter |
| Sensor: | Two reference grade platinum RTD clad in 316SS sheath |
| Material: | Wetted metal components: 316SS |
| Power: | 24VDC Standard (12VDC or 115/230VAC optional) |
| Power Dissipation: | < 2.5w |
| Electronics: | Microprocessor based |
| Electronics Enclosure: | Integral mount, NEMA 4 enclosure |
| Display: | High contrast photo-emissive OLED graphical display (Flow rate, Totalizer, Temperature) |
| Turndown: | 100 to 1 |
| Resolution: | 1000 to 1 |
| Low End Sensitivity: | 5 SFPM |
| Field Calibration Check: | Yes - Digital system allows raw signal validation (milli-watts) |
| Communications: | Modbus® compliant RS485 RTU communications |
| Approvals: |
CSA C22.2 (24VDC); Uli604, Class 1, Div 1 & 2, Grps A, B, C, D T4(24VDC); CE (AC Power or 24VDC) ATEX: Ex, nA IIC T4X (24VDC Model Only) |
| Field Reconfigurable: | Yes - Sage ADDRESSER or Sage DONGLE |
| Flow Accuracy: | +/- 0.5% of Full Scale +/-1 % of reading |
| Flow Repeatability: | 0.2% |
| Response Time: | 1 second |
| Gas Temperature Range: | -40° TO 200° STD (if higher temperature needed, contact Sage) |
| Gas Pressure: | 500 PSIG (if higher pressure needed, contact Sage) |
| Flow Output: | 4 to 20 mA for rate; 24VDC pulse for totalized value |
| Temperature Output: | Through Modbus® only |
| Ambient Temperature: | -4° F TO 150° F |
| Probe Style / Length: | 1/2" OD Probe (3/4" optional) Lengths 6" to 36" |
| Relays: | N/A |
| Flow Conditioning: | Captive Flow Conditioners available upon request with meter purchase |
![]() |
Sage SRP Specifications Remote Style Prime In-line Mass Flow Meter | ![]() |
| Sage Prime Thermal Mass Flow Meter | Document No. 100-0110 Rev. 8 |
| General Information | |
|---|---|
| Style: | Remote In-line Mass Flow Meter |
| Sensor: | Two reference grade platinum RTD clad in 316SS sheath |
| Material: | Wetted metal components: 316SS |
| Power: | 24VDC Standard (12VDC or 115/230VAC optional) |
| Power Dissipation: | < 2.5w |
| Electronics: | Microprocessor based |
| Probe Enclosure: | Junction Box is Explosion Proof, Class 1, Div 1 & 2, Group B, C, D (no electronics) |
| Transmitter Enclosure: | Remote mount, NEMA 4 enclosure |
| Display: | High contrast photo-emissive OLED graphical display (Flow rate, Totalizer, Temperature) |
| Turndown: | 100 to 1 |
| Resolution: | 1000 to 1 |
| Low End Sensitivity: | 5 SFPM |
| Field Calibration Check: | Yes - Digital system allows raw signal validation (milli-watts) |
| Communications: | Modbus® compliant RS485 RTU communications |
| Approvals: | CSA C22.2 (24VDC); Uli604, Class 1, Div 1 & 2, Grps A, B, C, D T4(24VDC); CE (AC Power or 24VDC) ATEX: Ex, nA IIC T4X (24VDC Model Only) |
| Field Reconfigurable: | Yes - Sage ADDRESSER or Sage DONGLE |
| Flow Accuracy: | +/- 0.5% of Full Scale +/-1 % of reading |
| Flow Repeatability: | 0.2% |
| Response Time: | 1 second |
| Gas Temperature Range: | -40° TO 200° STD (if higher temperature needed, contact Sage) |
| Gas Pressure: | 500 PSIG (if higher pressure needed, contact Sage) |
| Flow Output: | 4 to 20 mA for rate; 24VDC pulse for totalized value |
| Temperature Output: | Through Modbus® only |
| Ambient Temperature: | -4° F TO 150° F |
| Flow Body: |
316SS Schedule 40 Flow Bodies sized from 1/4" x 6" long to 4" to 12" long. Male NPT ends standard (Flanges and other options available) |
| Cable Length: | 25' Standard (max length 1000') |
| Relays: | N/A |
| Flow Conditioning: | Flow Conditions are built into In-line Style Flow Bodies from 1/2" to 4" |
![]() |
Sage SRP Specifications Remote Style Prime Insertion Mass Flow Meter | ![]() |
| Sage Prime Thermal Mass Flow Meter | Document No. 100-0109 Rev. 6 |
| General Information | |
|---|---|
| Style: | Remote In-line Mass Flow Meter |
| Sensor: | Two reference grade platinum RTD clad in 316SS sheath |
| Material: | Wetted metal components: 316SS |
| Power: | 24VDC Standard (12VDC or 115/230VAC optional) |
| Power Dissipation: | < 2.5w |
| Electronics: | Remote-Style Microprocessor based |
| Probe Enclosure: | Junction Box is Explosion Proof, Class 1, Div 1 & 2, Group B, C, D (no electronics) |
| Transmitter Enclosure: | Remote mount, NEMA 4 enclosure |
| Display: | High contrast photo-emissive OLED graphical display (Flow rate, Totalizer, Temperature) |
| Turndown: | 100 to 1 |
| Resolution: | 1000 to 1 |
| Low End Sensitivity: | 5 SFPM |
| Field Calibration Check: | Yes - Digital system allows raw signal validation (milli-watts) |
| Communications: | Modbus® compliant RS485 RTU communications |
| Approvals: | CSA C22.2 (24VDC); Uli604, Class 1, Div 1 & 2, Grps A, B, C, D T4(24VDC); CE (AC Power or 24VDC) ATEX: Ex, nA IIC T4X (24VDC Model Only) |
| Field Reconfigurable: | Yes - Sage ADDRESSER or Sage DONGLE |
| Flow Accuracy: | +/- 0.5% of Full Scale +/-1 % of reading |
| Flow Repeatability: | 0.2% |
| Response Time: | 1 second |
| Gas Temperature Range: | -40° TO 200° STD (if higher temperature needed, contact Sage) |
| Gas Pressure: | 500 PSIG (if higher pressure needed, contact Sage) |
| Flow Output: | 4 to 20 mA for rate; 24VDC pulse for totalized value |
| Temperature Output: | Through Modbus® only |
| Ambient Temperature: | -4° F TO 150° F |
| Probe Style / Length: | 1/2" OD Probe (3/4" optional) Lengths 6" to 36" |
| Relays: | N/A |
| Cable Length: | 25' Standard (max length 1000') |
| Flow Conditioning: | Captive Flow Conditioners available upon request with meter purchase |
To contact Sage for your inquiry, please select the appropriate tab. We will respond to your inquiry or quote request as soon as possible.
This form will be directed to Phil Hickerson, International Sales Manager, who will promptly respond to your inquiry
Phil Hickerson